Basic specifications
| model |
PTR50
|
| max. working pressure |
7.832 psi
|
| max. working pressure |
540 / 54 (bar/Mpa)
|
| battery included |
no
|
Performance
| spreading stroke 1st plunger |
405 mm
|
| spreading stroke 1st plunger |
15,9 in
|
| spreading stroke 2nd plunger |
382 mm
|
| spreading stroke 2nd plunger |
15 in
|
| total spreading stroke |
787 mm
|
| total spreading stroke |
31 in
|
| retracted length |
578 mm
|
| retracted length |
22,8 in
|
| extended length |
1.365 mm
|
| extended length |
53,7 in
|
| max. spreading force 1st plunger |
30.574 lbf
|
| max. spreading force 1st plunger |
136 / 13.9 (kN/t)
|
| max. spreading force 2nd plunger |
14.613 lbf
|
| max. spreading force 2nd plunger |
65 / 6.6 (kN/t)
|
| protection rate |
IP57
|
| sound emission @ 1m/3.25ft |
73 dB(A)
|
| sound emission @ 4m/13ft |
64 dB(A)
|
| vibration level |
<2.5 m/s²
|
| directives |
2006/42/EC, 2014/30/EU
|
General specifications
| hydraulic oil type |
ISO-L HV VG 36
|
| number of plungers |
2
|
Dimensions, weight and temperature
| weight, ready for use |
19,9 kg
|
| weight, ready for use |
43,9 lb
|
| temperature range |
-20 + 55 °C
|
| temperature range |
-4 + 131 °F
|
| weight excl. battery |
18,4 kg
|
| weight excl. battery |
40,6 lb
|
| dimensions (AxBxC) |
578 x 256 x 443 mm
|
| dimensions (AxBxC) |
22.8 x 10.1 x 17.4 in
|
Safety factors / tests
| hydraulic safety factor |
2:1
|
| endurance test tool |
1000 cycles of spreading while the tool is loaded
|
| endurance test dead man’s handle |
6000 cycles
|
Norms
| EN 13204 classification |
TR136/405-65/382-19.9
|
| EN 13204 compliant |
yes
|
| NFPA 1936, HSF |
136 kN
|
| NFPA 1936, HSF |
13,9 t
|
| NFPA 1936, HSF |
30.574 lbf
|
| NFPA 1936, HSF |
136 / 13.9 (kN/t)
|
| NFPA 1936, LSF |
65 kN
|
| NFPA 1936, LSF |
6,6 t
|
| NFPA 1936, LSF |
14.613 lbf
|
| NFPA 1936, LSF |
65 / 6.6 (kN/t)
|
| NFPA 1936 compliant |
yes
|